AWG
18 (Solid) Bare Copper Shielded |
|
Aero
P/N |
#
of Pair |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
2230/1 |
2 |
.006 |
.010 |
.206 |
33 |
2430/1 |
4 |
.006 |
.010 |
.242 |
57 |
2830/1 |
8 |
.006 |
.010 |
.319 |
107 |
2030/1 |
10 |
.006 |
.012 |
.366 |
131 |
2130-25/1 |
25 |
.006 |
.015 |
.533 |
313 |
|
|
|
|
|
|
AWG
18 (Solid) Bare Copper Unshielded |
|
Aero
P/N |
#
of Pair |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
2231/1 |
2 |
.006 |
.010 |
.202 |
28 |
2431/1 |
4 |
.006 |
.010 |
.238 |
52 |
2631/1 |
6 |
.006 |
.012 |
.284 |
78 |
2031/1 |
10 |
.006 |
.012 |
.362 |
125 |
|
|
|
|
|
|
AWG
18 (Solid) Bare Copper Ind. Shielded |
|
Aero
P/N |
#
of Pair |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
2232/1† |
2 |
.006 |
.010 |
.235 |
34 |
|
|
|
|
|
|
AWG
16 (Solid) Bare Copper Shielded |
|
Aero
P/N |
#
of Pair |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
2220/1 |
2 |
.007 |
.010 |
.251 |
51 |
|
|
|
|
|
|
AWG
16 (Solid) Bare Copper Unshielded |
|
Aero
P/N |
#
of Pair |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
2221/1 |
2 |
.007 |
.010 |
.247 |
43 |
|
|
|
|
|
|
|
|
Specifications |
|
Conductor:
Solid B.C.
Insulation:
FEP or
Halar (ECTFE) Add "HL" to P/N
Color Code:
Chart 3
† Common drain wire
Jackets Available:
FEP (200°C) or
PVDF (150°C) Add "K" to P/N or
Plenum PVC Jacket available
Industry Approvals:
NEC Article 725-CL2P or
NEC Article 800-CMP
PCC FT6-C(UL) (CMP only)
Impedance: (FEP only)
AWG 18:
Unshielded 72 Ohms Nom.
Overall Shield 70 Ohms Nom.
Individual Shielded 37 Ohms Nom.
AWG 16:
Unshielded 70 Ohms Nom.
Overall Shield 68 Ohms Nom.
|
Vel. of Propagation: (FEP
only)
69% Nom.
Capacitance: (FEP only)
AWG 18:
Unshielded 20 pF/ft.
Overall Shield 22 pF/ft
Individual Shield 40 pF/ft
AWG 16:
Unshielded 21 pF/ft
Overall Shield 23 pF/ft
Temperature Rating:
-80°C to +200°C (FEP/FEP)
-20°C to +150°C (FEP/PVDF)
-20°C to +150°C (Halar/PVDF)
Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels) |