AWG
22 (7x30) Tinned Copper
|
Request A Quote |
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
|
2 |
.010 |
.010 |
.145 |
19 |
|
3 |
.010 |
.010 |
.153 |
23 |
|
4 |
.010 |
.010 |
.166 |
27 |
|
5 |
.010 |
.010 |
.180 |
32 |
|
6 |
.010 |
.010 |
.195 |
37 |
|
7 |
.010 |
.010 |
.195 |
41 |
|
8 |
.010 |
.012 |
.252 |
57 |
TC229B |
9 |
.010 |
.012 |
.252 |
60 |
TC2212B |
12 |
.010 |
.012 |
.260 |
71 |
|
|
|
|
|
|
AWG 20 (7x28) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
|
2 |
.010 |
.010 |
.161 |
24 |
|
3 |
.010 |
.010 |
.170 |
30 |
|
4 |
.010 |
.010 |
.185 |
37 |
|
5 |
.010 |
.010 |
.202 |
44 |
|
6 |
.010 |
.010 |
.219 |
51 |
|
7 |
.010 |
.010 |
.219 |
56 |
|
8 |
.010 |
.012 |
.284 |
76 |
TC209B |
9 |
.010 |
.012 |
.284 |
81 |
TC2012B |
12 |
.010 |
.012 |
.293 |
97 |
|
|
|
|
|
|
AWG
18 (7x26) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
|
2 |
.010 |
.010 |
.181 |
30 |
|
3 |
.010 |
.010 |
.191 |
38 |
|
4 |
.010 |
.010 |
.212 |
46 |
|
5 |
.010 |
.010 |
.229 |
55 |
|
6 |
.010 |
.010 |
.252 |
71 |
|
7 |
.010 |
.010 |
.252 |
79 |
|
8 |
.010 |
.012 |
.324 |
96 |
TC189B |
9 |
.010 |
.012 |
.324 |
103 |
TC1812B |
12 |
.010 |
.012 |
.334 |
126 |
|
|
|
|
|
|
|
|
Specifications |
|
Conductor:
Stranded TInned Plated Copper
Insulation:
FEP
Color Code:
Chart 1
Shield:
90% TC Braid
Jacket:
FEP
Vel. of Propagation:
69% Nom.
Capacitance:
(AWG 18) 30 pF/FT Nom.
(AWG 20) 26.6 pF/FT Nom.
(AWG 22) 23.5 pF/FT Nom.
|
Voltage:
600 Volts
Temperature Rating:
-80°C to +200°C
Industry Approvals & Compliance:
RoHS Compliant
Passes Flame Test UL910 / 1581 / NFPA 262 / FT-6 /
IEEE-383
Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)
Resistant to Chemical, Gas, Oil, Sunlight, and Water
|