AWG
22 (7x30) Tinned Copper
|
Request A Quote |
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
|
2 |
.010 |
.010 |
.120 |
10 |
|
3 |
.010 |
.010 |
.128 |
13 |
|
4 |
.010 |
.010 |
.141 |
17 |
|
5 |
.010 |
.010 |
.155 |
21 |
|
6 |
.010 |
.010 |
.170 |
25 |
|
7 |
.010 |
.010 |
.170 |
28 |
|
8 |
.010 |
.012 |
.170 |
33 |
TC229U |
9 |
.010 |
.012 |
.220 |
36 |
TC2212U |
12 |
.010 |
.012 |
.228 |
46 |
|
|
|
|
|
|
AWG 20 (7x28) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
|
2 |
.010 |
.010 |
.136 |
14 |
|
3 |
.010 |
.010 |
.145 |
19 |
|
4 |
.010 |
.010 |
.160 |
25 |
|
5 |
.010 |
.010 |
.177 |
31 |
|
6 |
.010 |
.010 |
194 |
36 |
|
7 |
.010 |
.010 |
.194 |
42 |
|
8 |
.010 |
.010 |
.252 |
49 |
TC209U |
9 |
.010 |
.010 |
.252 |
54 |
TC2012U |
12 |
.010 |
.012 |
.265 |
71 |
|
|
|
|
|
|
AWG
18 (7x26) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
|
2 |
.010 |
.010 |
.156 |
18 |
|
3 |
.010 |
.010 |
.166 |
26 |
|
4 |
.010 |
.010 |
.184 |
33 |
|
5 |
.010 |
.010 |
.204 |
41 |
|
6 |
.010 |
.010 |
.224 |
48 |
|
7 |
.010 |
.010 |
.224 |
55 |
|
8 |
.010 |
.010 |
.296 |
66 |
TC189U |
9 |
.010 |
.010 |
.296 |
73 |
TC1812U |
12 |
.010 |
.010 |
.306 |
94 |
|
|
|
|
|
|
|
|
Specifications |
|
Conductor:
Stranded TInned Plated Copper
Insulation:
FEP
Color Code:
Chart 1
Jacket:
FEP
Vel. of Propagation:
69% Nom.
Capacitance:
(AWG 18) 18.4 pF/FT Nom.
(AWG 20) 16.7 pF/FT Nom.
(AWG 22) 15.2 pF/FT Nom.
|
Voltage:
600 Volts
Temperature Rating:
-80°C to +200°C
Industry Approvals & Compliance:
RoHS Compliant
Passes Flame Test UL910 / 1581 / NFPA 262 / FT-6 /
IEEE-383
Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)
Resistant to Chemical, Gas, Oil, Sunlight, and Water
|