AWG
18 (7x26) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
8018-2 |
2 |
.020 |
.045 |
.264 |
46 |
8018-3 |
3 |
.020 |
.045 |
.279 |
64 |
8018-4 |
4 |
.020 |
.045 |
.302 |
91 |
8018-7 |
7 |
.020 |
.045 |
.314 |
91 |
8018-12 |
12 |
.020 |
.060 |
.485 |
174 |
|
|
|
|
|
|
AWG
16 (7x24) Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
8017-2 |
2 |
.020 |
.045 |
.276 |
53 |
8017-3 |
3 |
.020 |
.045 |
.299 |
71 |
8017-4 |
4 |
.020 |
.045 |
.314 |
80 |
8017-6 |
6 |
.020 |
.045 |
.369 |
110 |
8017-9 |
9 |
.020 |
.045 |
.462 |
157 |
8017-19 |
19 |
.020 |
.060 |
.585 |
307 |
|
|
|
|
|
|
AWG
14 (19x.0150") Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
8014-2 |
2 |
.020 |
.045 |
.304 |
66 |
8014-3 |
3 |
.020 |
.045 |
.330 |
68 |
8014-6 |
6 |
.020 |
.045 |
.411 |
146 |
8014-7 |
7 |
.020 |
.045 |
.411 |
162 |
|
|
|
|
|
|
AWG
12 (19x.0185") Tinned Copper |
|
Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
8012-2 |
2 |
.020 |
.045 |
.338 |
86 |
8012-4 |
4 |
.020 |
.045 |
.389 |
141 |
8012-5 |
5 |
.020 |
.045 |
.425 |
170 |
8012-6 |
6 |
.020 |
.045 |
.462 |
199 |
8012-7 |
7 |
.020 |
.045 |
.462 |
223 |
8012-12 |
12 |
.020 |
.060 |
.635 |
388 |
8012-19 |
19 |
.020 |
.060 |
.707 |
575 |
|
|
|
|
|
|
|
|
Specifications |
|
Conductor:
Stranded TC
Insulation:
FEP
Color Code:
Chart 1
Jacket:
FEP (200°C)
Industry Approvals:
UL Type TC
Impedance:
(AWG 18) 128 Ohms Nom.
(AWG 16) 118 Ohms Nom.
(AWG 14) 105 Ohms Nom.
(AWG 12) 94 Ohms Nom.
|
Vel. of Propagation:
69% Nom.
Capacitance:
(AWG 18) 11.5 pF/FT Nom.
(AWG 16) 12.5 pF/FT Nom.
(AWG 14) 14 pF/FT Nom.
(AWG 12) 15 pF/FT Nom.
Voltage:
600 Volts
Temperature Rating:
-80°C to +200°C |